1 × 1200 kVA, design version
10 / 0.4 kVDry cast transformers with aluminum winding in the base; copper winding is a separate option.

Visualization of design execution. The layout, inputs and facades are specified after approval of the single-line diagram.
Industrial transformer substation
Project article: BKTP-1200-10-04
Compact block substation for industrial, commercial and infrastructure facilities: 10 kV switchgear, dry transformer with a design capacity of 1200 kVA and 0.4 kV switchgear.
In the manufacturer's catalog, the closest standard size is 1250 kVA. The design for 1200 kVA and the permissible load are confirmed by the factory technical and commercial proposal. Price, climatic modification and EXW/FOB/DDP conditions are fixed after agreeing on a single-line diagram.
Technical Data
Design parameters. The final configuration is confirmed by a single-line diagram and a technical and commercial proposal.
Model architecture
In the manufacturer's catalog, the closest standard size is 1250 kVA. The design for 1200 kVA and the permissible load are confirmed by the factory technical and commercial proposal.
Dry cast transformers with aluminum winding in the base; copper winding is a separate option.
Busbars, input and output devices are selected according to the design current, selectivity and short-circuit current.
Production site
Video provided by potential manufacturer during technical development. It shows the assembly of NKU, switching equipment and finished modules; the specific configuration of HELIKOR is confirmed by FAT.
Complete delivery
The substation is equipped as a factory module, and current-carrying parts are calculated based on actual power and short-circuit currents.
KRU/KSO or compact switchgear with switching, protection, measurement and cable entries.
1 × 1200 kVA, design design in safe modular design.
Busbars, incoming, sectional and outgoing devices are selected according to load, selectivity and short-circuit current.
Heating, ventilation, auxiliary needs, thermal control and fire safety equipment are collected and checked before shipment.
Contents of the project supply
The basic development includes 10 kV switchgear, dry transformer, 0.4 kV switchgear, microprocessor relay protection and automation, commercial accounting, auxiliary and thermal protection cabinets, ventilation, heating, lighting, grounding and fire alarm.
Engineering check
Rated current: about 1.73 kA. The rating of busbars, input and sectional devices is confirmed by the manufacturer based on transformers, permissible overload and short-circuit current.
Project equipment
We will prepare an EXW/FOB or DDP offer to the site, disclosing the composition, logistics, duties, 22% VAT and unloading boundaries.