1 × 3200 kVA; SCB13-3150 kVA - compatible equivalent
10 / 0.4 kVDry cast transformers with aluminum winding in the base; copper winding is a separate option.

Visualization of design execution. The layout, inputs and facades are specified after approval of the single-line diagram.
Industrial transformer substation
Project article: BKTP-3200-10-04
Single-transformer block substation for industrial and computing loads: 10 kV switchgear, dry transformer 3200 kVA, 0.4 kV switchgear and engineering systems in a modular building.
The power of 3200 kVA is specified by the project. Option SCB13-3150 kVA is used only after technical approval. Price, climatic modification and EXW/FOB/DDP conditions are fixed after agreeing on a single-line diagram.
Technical Data
Design parameters. The final configuration is confirmed by a single-line diagram and a technical and commercial proposal.
Model architecture
The power of 3200 kVA is specified by the project. Option SCB13-3150 kVA is used only after technical approval.
Dry cast transformers with aluminum winding in the base; copper winding is a separate option.
Busbars, input and output devices are selected according to the design current, selectivity and short-circuit current.
Production site
Video provided by potential manufacturer during technical development. It shows the assembly of NKU, switching equipment and finished modules; the specific configuration of HELIKOR is confirmed by FAT.
Complete delivery
The substation is equipped as a factory module, and current-carrying parts are calculated based on actual power and short-circuit currents.
KRU/KSO or compact switchgear with switching, protection, measurement and cable entries.
1 × 3200 kVA; SCB13-3150 kVA is a compatible equivalent in a safe modular design.
Busbars, incoming, sectional and outgoing devices are selected according to load, selectivity and short-circuit current.
Heating, ventilation, auxiliary needs, thermal control and fire safety equipment are collected and checked before shipment.
Contents of the project supply
The basic development includes 10 kV switchgear, dry transformer, 0.4 kV switchgear, microprocessor relay protection and automation, commercial accounting, auxiliary and thermal protection cabinets, ventilation, heating, lighting, grounding and fire alarm.
Engineering check
Rated current: about 4.6 kA. The rating of busbars, input and sectional devices is confirmed by the manufacturer based on transformers, permissible overload and short-circuit current.
Project equipment
We will prepare an EXW/FOB or DDP offer to the site, disclosing the composition, logistics, duties, 22% VAT and unloading boundaries.